Product Summary
The E-Flex Guard is an Insulation Protector for Refrigeration Piping on Outdoor applications that complies with mandatory requirements where adhesive tapes are no longer allowed by code, and as specifically prescribed by the new Building/Residential/Energy Codes. Engineered PVC Material is UV/Weather Resistant and a Class II Vapor Retarder to comply with new energy codes, and sustainably protects outdoor pipe insulation.
UV Weather Protector & Vapor Retarder (All-In-One)!
- Meets mandatory Building Codes, Energy, Residential, Mechanical, and Green Codes
- Made in The USA
- Outdoor UV/Weather Grade Resistant Construction
- Self-Gripping, Dual-Bonded Hook & Loop Fastening System
- Removable/Reusable for Maintenance
- Protector and Class II Vapor Retarder (All-In-One)
- Meets ASTM G153 Weatherization and UV
- Meets ASTM E-96 Water/Vapor Permeability
Weather and Physical Damage Protection
6 Foot Length Series
Model # |
Color |
Product Description |
72E-B |
Black |
AIREX E-FLEX GUARD (6' ft) Length Fits over: 1/2" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube |
72C-B |
Black |
AIREX E-FLEX GUARD (6' ft) Length Fits over: 3/4" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube or 1/2" wall thickness pipe insulation with 1-1/8" tube |
72X-B |
Black |
AIREX E-FLEX GUARD (6' ft) Length Fits over: 1" wall thickness pipe insulation with 3/4", 7/8" tube or 3/4" wall thickness pipe insulation with 1-1/8" tube |
72E-W |
White |
AIREX E-FLEX GUARD (6' ft) Length Fits over: 1/2" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube |
72C-W |
White |
AIREX E-FLEX GUARD (6' ft) Length Fits over: 3/4" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube or 1/2" wall thickness pipe insulation with 1-1/8" tube |
72X-W |
White |
AIREX E-FLEX GUARD (6' ft) Length Fits over: 1" wall thickness pipe insulation with 3/4", 7/8" tube or 3/4" wall thickness pipe insulation with 1-1/8" tube |
75 Foot Length Series
Model # |
Color |
Product Description |
750E-B |
Black |
AIREX E-FLEX GUARD (75' ft) Length Fits over: 1/2" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube |
750C-B |
Black |
AIREX E-FLEX GUARD (75' ft) Length Fits over: 3/4" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube or 1/2" wall thickness pipe insulation with 1-1/8" tube |
750X-B |
Black |
AIREX E-FLEX GUARD (75' ft) Length Fits over: 1" wall thickness pipe insulation with 3/4", 7/8" tube or 3/4" wall thickness pipe insulation with 1-1/8" tube |
750E-W |
White |
AIREX E-FLEX GUARD (75' ft) Length Fits over: 1/2" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube |
750C-W |
White |
AIREX E-FLEX GUARD (75' ft) Length Fits over: 3/4" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube or 1/2" wall thickness pipe insulation with 1-1/8" tube |
750X-W |
White |
AIREX E-FLEX GUARD (75' ft) Length Fits over: 1" wall thickness pipe insulation with 3/4", 7/8" tube or 3/4" wall thickness pipe insulation with 1-1/8" tube |
90 Degree Elbow Series
Model # |
Color |
Product Description |
90E-B |
Black |
AIREX E-FLEX GUARD 90° Fits over: 1/2" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube |
90C-B |
Black |
AIREX E-FLEX GUARD 90° Fits over: 3/4" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube or 1/2" wall thickness pipe insulation with 1-1/8" tube |
90X-B |
Black |
AIREX E-FLEX GUARD 90° Fits over: 1" wall thickness pipe insulation with 3/4", 7/8" tube or 3/4" wall thickness pipe insulation with 1-1/8" tube |
90E-W |
White |
AIREX E-FLEX GUARD 90° Fits over: 1/2" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube |
90C-W |
White |
AIREX E-FLEX GUARD 90° Fits over: 3/4" wall thickness pipe insulation with 5/8", 3/4”, 7/8" tube or 1/2" wall thickness pipe insulation with 1-1/8" tube |
90X-W |
White |
AIREX E-FLEX GUARD 90° Fits over: 1" wall thickness pipe insulation with 3/4", 7/8" tube or 3/4" wall thickness pipe insulation with 1-1/8" tube |
Product Description
AIREX E-FLEX GUARD – Insulation Protection for Refrigeration Piping on Outdoor applications. The Flexible PVC Insulation Protector complies with mandatory requirements where adhesive tapes are no longer allowed by code, and as specifically prescribed by the new Building/Residential/Energy Codes. Engineered PVC Material is UV/Weather Resistant and a Class II Vapor Retarder to comply with new energy codes, and sustainably protects outdoor pipe insulation (All-In-One).
Insulation Protection System consists of an Engineered and Formulated PVC Sheeted Material to Specifically protect outdoor piping insulation, it is designed and manufactured as a flexible PVC jacket, with a permanent non-adhesive dual bonded self-gripping integral fastening system. The fastening system allows the protector to be Removable and Reusable for ease of Maintenance, as required by code bodies. The Insulation Protector consists of resilient PVC Material that is Class “A” Fire/Smoke Rated, Vapor Retarder, Anti-Fungal, and Anti-Microbial. AIREX E-FLEX GUARD is available in standard piping insulation diameter sizes, and lengths of up to 75 feet of continuous non-interrupted runs (allows for field applied cut to length requirements). Individual 90-degree angle Insulation Protection Fittings are also available. The Insulation Protection System completes a code compliant, aesthetic, and secure professional finish installation. AIREX E-FLEX GUARD is the sustainable solution to maintain energy efficiency and optimum performance of HVAC equipment.
Approved Product & Material Testing
ASTM G153 – Weatherization and UV Exposure
ASTM E96 – Water/Vapor Permeability
ASTM G21 – Anti-Fungal/Anti-Microbial
ASTM D412 - Tension Deformation Test (UV Exposure & Water Immersion)
ASTM D570 – Water Absorption
ASTM E84/UL 723 - Flame and Smoke Rating 25/450
Codes & Standards Compliance
- IECC - 2012 Protection of Piping Insulation – Commercial Section C403.2.8.1
- IECC - 2015 Protection of Piping Insulation – Commercial Section C403.2.10.1
- IRC - 2018 Refrigerant Line Insulation Protection – M1411.6.1 - Section N1103.4.1
- California Building Energy Standards (Title 24) 2013 - Residential & Commercial Requirement for Pipe Insulation120.3 – Section: 150.0(j) 3a & b
- California Building Energy Standards (Title 24) 2016 - Residential & Commercial Requirement for Pipe Insulation120.3 – Section: 150.0(j) 2 & 3 – Section 150.0(m) 9
- ANSI/ASHRAE/IESNA Standard 90.1 - 2004, 2007, 2010